Re: Crossover cable DB50 to DB50

From: Peng Zheng (zpnist@yahoo.com)
Date: Mon Nov 25 2002 - 18:19:17 GMT-3


When I set the clock rate on DCE side(I also tried on
DTE side in case they label it wrong), it seems OK.
But if I run sh run:
There is no clock rate under the interface.

And I think if the cable is OK, I think the serial
should be up even if you didn't set the clock rate.
 

--- Neil Moore <neil@droopy.com> wrote:
> Hello there,
> have you set the clockrate and Interface info? One
> side needs a clockrate
> the other doesn't
>
> interface Serial1
> description Other Router S0
> no ip address
> encapsulation frame-relay
> clockrate 2000000
> frame-relay intf-type dce
> ----------------------------------------
> Neil Moore CCIE#10044
> ----- Original Message -----
> From: "Peng Zheng" <zpnist@yahoo.com>
> To: <ccielab@groupstudy.com>
> Sent: Monday, November 25, 2002 2:56 PM
> Subject: Crossover cable DB50 to DB50
>
>
> > I got two Crossover cable DB50 to DB50, when I
> tried
> > to connect two Cisco 3000 routers, on both sides:
> >
> > Serial0 is down, line protocol is down
> >
> > But both serial port is OK when I connect them to
> a
> > Cisco 2501 through a cable DB50 to DB60.
> >
> > Is there any other reason except the cable is
> wrong?
> >
> > I already tried both of them, neither of them
> work.
> >
> >
> > __________________________________________________
> > Do you Yahoo!?
> > Yahoo! Mail Plus  Powerful. Affordable. Sign up
> now.
> > http://mailplus.yahoo.com



This archive was generated by hypermail 2.1.4 : Tue Dec 03 2002 - 07:23:10 GMT-3