RIP version one

From: Sam.MicroGate@usa.telekom.de
Date: Mon Nov 11 2002 - 14:59:15 GMT-3


Hello everyone,

I have two routers, R1 and R2, connected together through a serial
interface. The configuration of the two routers area stated below. In R2, I
can not ping the loopback interfaces of R1. The reason of this because R2 is
receiving a summary address at the network boundary, 150.50.0.0/16.
Therefore R2 would install the route with the longest match and lower
administrative distance which is 150.50.2.2/32 in its routing table and
ignore 150.50.0.0/16. Any remedy for this problem? Please include a sample
config. If you can. Thanks.

R1:

Interface serial 0
Ip address 192.168.1.1 255.255.255.0

Interface loopback 0
Ip address 150.50.10.1 255.255.255.255

Interface loopback 1
Ip address 150.50.11.1 255.255.255.255

Router rip
Redistribute connected metric 5
Network 192.168.1.0

R2:
Interface serial 0
Ip address 192.168.1.2 255.255.255.0

Interface loopback 0
Ip address 150.50.2.2 255.255.255.255

Router rip
Network 192.168.1.0



This archive was generated by hypermail 2.1.4 : Tue Dec 03 2002 - 07:22:56 GMT-3