From: miken (miken@sisna.com)
Date: Thu Nov 07 2002 - 03:36:49 GMT-3
Yes, if you are asking about which interface the DTE and DCE end of the
cable is attached to. You would set the clock rate on the DCE device which
does
not have to be the frame switch. "frame-relay intf-type dce" still needs to
be in the frame switch serial interface. I think you need this to configure
the frame-relay route command but that doesn't mean that is where the DCE
side of the cable is plugged into.
HTH,
Mike Nygard
----- Original Message -----
From: "Fan Shan" <fansh@publicf.bta.net.cn>
To: "Ccielab@Groupstudy.Com" <ccielab@groupstudy.com>
Sent: Wednesday, November 06, 2002 10:39 PM
Subject: Can FR switch be configured as DTE?
> Can FR Switch be configured as DTE and the other side configured as DCE?