From: MADMAN (dave@interprise.com)
Date: Wed Oct 23 2002 - 15:50:06 GMT-3
Don't know about the nice part but... This seems to be talking about
two differant things. As far I as know the idle timer will keep the
connection form being dropped but no the multilink.
I recall a while back that 1 and 2 were no longer valid so I use 3 if
I want a low threshold to bring up a second link but the idle timer will
not keep or bring up the second or subsequent links of a bundle.
Dave
Luis Miguel Gil wrote:
>
> Hi all,
> I don't understand this statement (DocCD, IOS release 12.1):
>
> "When multilink PPP is configured, the dialer-load threshold 1 command no
> longer keeps a multilink bundle of n links connected indefinitely and the
> dialer-load threshold 2 command no longer keeps a multilink bundle of 2
> links connected indefinitely. If you want a multilink bundle to be connected
> indefinitely, you must set a very high idle timer"
>
> Is there any nice person to "translate" this for me ?
>
> thanks in advance,
> Luis Miguel.
-- David Madland CCIE# 2016 Sr. Network Engineer Qwest Communications 612-664-3367"You don't make the poor richer by making the rich poorer." --Winston Churchill