RE: Dialer watch

From: Ashok.Gupta (Ashok.Gupta@gmconsultants.com)
Date: Tue Oct 15 2002 - 15:43:31 GMT-3


floating static

Regds

Ashok

-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com]On Behalf Of
Azhar Mehmood
Sent: 15 October 2002 17:09
To: ccielab@groupstudy.com
Subject: Dialer watch

Hi,

I have a router R1 ehich has 3 exit points to reach a specific subnet:

1. Ethernet
2. Serial
3. ISDN

As long the route over ethernet is available it's prefered over all other,
after it has gone serial is prefered and as third option the ISDN Link.

Now my problem is how to keep ISDN Link down until both of the primary links
are available. I tried to acomplish it with dialer watch but as soon as the
ethernet is gone dialer watch triggers the call hence it brings it also down
again after idle-timeout.

My question is how to configure the router that it waits until both of the
link 're unavailable and triggering than an isdn call.

regards

AZHAR MEHMOOD
GERMANY