From: Ray Armstrong (ray.armstrong@data-evolution.net)
Date: Wed Sep 04 2002 - 11:52:52 GMT-3
Thanks for that.
Do you think an IOS change may be better ? obviously I'm restricted to 11.2
as the device has an RP and SP, and not a RSP.
It happens on all different types of interface processors, as I have tested
it.
regards,
RA.
----- Original Message -----
From: <Liban.Mohamed@mail.sprint.com>
To: <ccielab@groupstudy.com>; <ray.armstrong@data-evolution.net>
Sent: Wednesday, September 04, 2002 3:47 PM
Subject: RE: Problem Error Message.
> Hi,,
>
>
> this is what i found according to cisco...hope it helps.. that is why i
> like GSR better u can reload the LC only.
>
>
> 1. %CBUS-3-OUTHUNG: [chars]: tx[char] output hung ([hex] - [chars]),
> [chars]
> A transmission attempt on an interface has failed. The interface might
> not be attached to a cable or there might be a software problem.
>
>
>
>
>
>
>
> Liban Mohamed
> IP Engineer
> Sprintlink Internet Backbone Operation
>
>
> -----Original Message-----
> From: ray.armstrong [mailto:ray.armstrong@data-evolution.net]
> Sent: Wednesday, September 04, 2002 5:10 AM
> To: ccielab
> Subject: Problem Error Message.
>
>
> Hi,
>
> Anyone have any ideas why the FSIP in my 7010, would report this error
> message ?
>
> 01:23:27: %CBUS-3-OUTHUNG: Serial0/5: tx0 output hung (800E - queue
> full),
> interface
> 01:23:28: %CBUS-3-OUTHUNG: Serial0/4: tx0 output hung (800E - queue
> full),
> interface
>
> The serial interfaces are then rendered useless, unless you reload or
> clear
> the interfaces.
>
> This problem occurs intermittantly from 10 minutes up to 1 hour before
> it
> happens, but it always does.
>
> Extract from Sh Ver follows.
>
> IOS (tm) 7000 Software (C7000-JS-M), Version 11.2(12), RELEASE SOFTWARE
> (fc1)
>
> any offers ?
>
> rgds,
>
> RA.
This archive was generated by hypermail 2.1.4 : Mon Oct 07 2002 - 07:43:44 GMT-3