From: Balaji Siva (bsivasub@xxxxxxxxx)
Date: Thu Aug 08 2002 - 14:22:23 GMT-3
Let me try to answer them inline
-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com]On Behalf Of
Jaspreet Bhatia
Sent: Thursday, August 08, 2002 1:03 PM
To: ccielab@groupstudy.com
Subject: Switching questions ?
Folks,
I am doing Routopia LAB 2 and have a few question
about the switching part
1) Configure the forwarding delay on VLAN 1 to reflect that of a
spanning tree diameter of two switches. Ensure all other timers that
are used in conjunction with the forwarding delay are also changed in
the correct proportions.
#### set spantree root 1 dia 2
(this is automagicaly change the forwarding delay and timers basedon the
dia)
2) Have the switch respond to root link queries.
### configure backbone fast
3) Set a CAM entry and make sure it never times out. Ensure the host is
serviced 3 times more often
than any other host.
### configure static cam entry.
for the second part, i guess they are talking port priority to backplane.
(there is such thing
in cat3550 anyway)
TIA