Re: cable problem

From: Nick Shah (nshah@xxxxxxxxxxxxxx)
Date: Fri Jun 14 2002 - 02:53:09 GMT-3


   
Chenyan,

1a. Tighten cable (without breaking somethign ;)
1. Check encapsulation on both ends (both should be ppp or both should be
hdlc)
2. the DCE side should have a clock rate xxxx
3. both interfaces should be "no shut"
4. If still one or both sides are having line prot. down, do a "no
keepalive" under both the interfaces

rgds
Nick
----- Original Message -----
From: "chenyan" <chenyan@deeptht.com.cn>
To: "ccielab" <ccielab@groupstudy.com>
Sent: Friday, June 14, 2002 3:06 PM
Subject: cable problem

> hi,guys,one 2600 connecting to 2500 back-to-back, after setting the
clockrate there is still only one side's protocol down,why?