RE: Token ring switch configuration

From: absitech@xxxxxxxxxxxx
Date: Tue May 28 2002 - 09:35:20 GMT-3


   
If I understand your situation correctly,
it seems as if you're trying to create two TrCRF's (rings)
when you should be creating only one. After you
create the one TrCRF, apply it to the two ports that
are connected.

Later...

Robert Miller

------------------------------------------------
On Mon, 27 May 2002 21:35:22 -0700 (PDT), Paul <p_chopin@yahoo.com> wrote:

> Hi guys,
> I thought I knew this subject well, and looks like
> life
> (Cisco) proof me wrong. I'm doing lab - 2 token ring
> interface connected to same ring 200. When I'm trying
> to input ring value under TrCRF for the second
> interface it says, that this value(c8) has already
> been
> used, so I'm foreced to input different value and
> everything seems to work.
> When I shutdown both routers token ring interfaces
> the switch doesn't complain about ring value. But then
> the interfaces don't see each other (with multiring
> all).
> Am I doing something wrong? Or is it normal behavior?
> I'm confused.Please help
> Paul
>
>



This archive was generated by hypermail 2.1.4 : Thu Jun 13 2002 - 10:59:10 GMT-3