Re: Find the clock rate??

From: Maurice Flint (mflint@xxxxxxxxxx)
Date: Sun Mar 17 2002 - 15:42:51 GMT-3


   
I have C2600's and do not see the clock rate you mentioned. Is there a way to
determine the clock rate from the DCE device on a local DTE interface?

Thanks for your help.

"R. Benjamin Kessler" wrote:

> show controllers serial 0
>
> ~10 lines down from the top there will be a line that indicates the
> "received clockrate"
>
> -----Original Message-----
> From: nobody@groupstudy.com [mailto:nobody@groupstudy.com]On Behalf Of
> hSzeto Jeff
> Sent: Friday, March 15, 2002 6:57 AM
> To: ccielab@groupstudy.com
> Subject: Find the clock rate??
>
> Hi,
>
> My question may be elementary, but please help.
>
> If I can only access the DTE side,
> how can I find the clock rate of the DCE side ?
>
> I have tried to debug, the response follows
>
> R3#debug int s0
> Condition 1 set
>
> What is the meaning of that response?
>
> Thank you in advance.
>
> Jeff
>



This archive was generated by hypermail 2.1.4 : Thu Jun 13 2002 - 10:57:11 GMT-3