From: Peter Whittle (peter@xxxxxxxxxxxxxxxxxxxxxxxxxxx)
Date: Fri Feb 22 2002 - 16:49:11 GMT-3
Most certainly is!
If you connect them back to back via a T1 cross-over cable then you can
only practice ATM PVCs.
For SVCs you need an ATM switch with SVC call control processor and dual
T1 ATM interfaces.
I currently have a pair with the mft-T1/E1 re-configure as an E1 i/f (go
into ROMMON to change it). This does not matter to the ATM side of
things.
Config extract
controller E1 0
clock source internal
mode atm
interface ATM0
ip address 172.31.69.9 255.255.255.0
no atm ilmi-keepalive
pvc 0/101
protocol ip 172.31.69.6 broadcast
encapsulation aal5nlpid
!
Remember if you do not have an ATM switch then the vpi/vci must match at
both ends ie you must use the same at both ends.
eg rtr-A
pvc 0/101
rtr-B
pvc 0/101
Peter
In message <4.3.2.7.2.20020222111032.03011ec8@overnight.cisco.com>,
Jaspreet Bhatia <jasbhati@cisco.com> writes
>Folks,
> Is it possible to run ATM on MC 3810 with MFT interfaces
>connected to each other back to back and would a T1 crossover cable do the
>trick? Thanks
>
>Jaspreet
This archive was generated by hypermail 2.1.4 : Thu Jun 20 2002 - 13:46:30 GMT-3