RE: frame relay pvc inactive

From: Dennis Hess (dennis.hess@xxxxxxxxxxxxxxxxxxx)
Date: Thu Dec 27 2001 - 10:13:50 GMT-3


   
I had this exact same issue in my lab a few weeks ago and I can guarantee
you the configs were correct. Still no love on one interface. I reversed
the DTE-DCE cable, moved the clock to the other side, and it came right up.
I haven't had any time to investigate further why this is so. The IOS is
12.1(11) with 2 2500 routers. Reverse your cable and see what happens.

Dennis

-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com]On Behalf Of
Dennis.D.Adekola@britishairways.com
Sent: Wednesday, December 26, 2001 8:10 AM
To: Scott Morris
Cc: ccielab@groupstudy.com
Subject: RE: frame relay pvc inactive

You just read my mind scott

Have you looked at the status of the serial interfaces i.e sho int serial ?
Have you also cloked the right interfaces ?
Do you have a faulty physical interface ? (I did once)

Your configs look right
so it must be something basic

Dennis

"Scott Morris" <swm@emanon.com>@groupstudy.com on 26/12/2001 12:08:59

Please respond to "Scott Morris" <swm@emanon.com>

Sent by: nobody@groupstudy.com

To: "'wen jia yang'" <tonyblair
      <ccielab
cc:
bcc:
Subject: RE: frame relay pvc inactive

I'd look at some more basic issues. Try a "show controllers serial xxx"
on
the frame switch and remote router for dlci 200. Also, since you have CDP
enabled, check your "show cdp neighbors" and see if each router SEEs each
other.

Have you tried moving from serial0 to serial2 on the frame switch?

Scott

-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com]On Behalf Of
wen jia yang
Sent: Monday, December 24, 2001 9:04 PM
To: ccielab@groupstudy.com
Subject: frame relay pvc inactive

RouterA s0------s0 FrameSwitch s1------s0 RouterB
          dlci 200 dlci210

The following are the configs:
----------------------------------------------------------------------------

--------------------------------
Current configuration:
!
version 12.0
service timestamps debug uptime
service timestamps log uptime
no service password-encryption
!
hostname FrameSwitch
!
!
ip subnet-zero
frame-relay switching
!
!
!
!
!
interface Serial0
 no ip address
 no ip directed-broadcast
 encapsulation frame-relay
 no ip mroute-cache
no ip mroute-cache
 clockrate 64000
 cdp enable
 frame-relay lmi-type ansi
 frame-relay intf-type dce
 frame-relay route 200 interface Serial1 210
!
interface Serial1
 no ip address
 no ip directed-broadcast
 encapsulation frame-relay
 clockrate 64000
 cdp enable
 frame-relay lmi-type ansi
 frame-relay intf-type dce
 frame-relay route 210 interface Serial0 200
!
interface Serial2
 no ip address
 no ip directed-broadcast
 encapsulation frame-relay
 clockrate 64000
 cdp enable
 frame-relay lmi-type ansi
.
.
.
line con 0
 exec-timeout 0 0
 transport input none
line aux 0
line vty 0 4
 no login
!
end
----------------------------------------------------------------------------

------------------------------
Current configuration:
!
version 12.0
service timestamps debug uptime
service timestamps log uptime
no service password-encryption
service tcp-small-servers
!
hostname RouterA
!
!
ip subnet-zero
no ip domain-lookup
!
!
!
!
!
interface Ethernet0
 no ip address
 no ip directed-broadcast
 no ip route-cache
interface Serial0
 ip address 192.1.1.1 255.255.255.0
 no ip directed-broadcast
 encapsulation frame-relay
 no ip route-cache
 no ip mroute-cache
 frame-relay lmi-type ansi
!
interface Serial1
 no ip address
 no ip directed-broadcast
 no ip route-cache
 no ip mroute-cache
 clockrate 64000
!
interface TokenRing0
 no ip address
 no ip directed-broadcast
 no ip route-cache
 no ip mroute-cache
 shutdown
router rip
 network 192.1.1.0
 network 193.1.1.0
!
ip nat translation timeout never
ip nat translation tcp-timeout never
ip nat translation udp-timeout never
ip nat translation finrst-timeout never
ip nat translation syn-timeout never
ip nat translation dns-timeout never
ip nat translation icmp-timeout never
no ip classless
!
!
!
line con 0
 exec-timeout 0 0
 transport input none
line aux 0
 transport input all
line vty 0 4
no login
!
end
----------------------------------------------------------------------------

--------------------------------
Current configuration:
!
version 12.0
service timestamps debug uptime
service timestamps log uptime
no service password-encryption
!
hostname RouterB
!
!
ip subnet-zero
no ip domain-lookup
frame-relay de-list 3 protocol ip gt 512
!
!
!
!
!
interface Ethernet0
 no ip address
 no ip directed-broadcast
!interface Serial0
 ip address 192.1.1.2 255.255.255.0
 no ip directed-broadcast
 encapsulation frame-relay
 no ip mroute-cache
 frame-relay lmi-type ansi
!
interface Serial1
 no ip address
 no ip directed-broadcast
 clockrate 64000
!
router rip
 network 192.1.1.0
!
ip nat translation timeout never
ip nat translation tcp-timeout never
ip nat translation udp-timeout never
ip nat translation finrst-timeout never
ip nat translation syn-timeout never
ip nat translation dns-timeout never
ip nat translation icmp-timeout never
no ip classless
!
!
!
line con 0
 exec-timeout 0 0
 transport input none
line aux 0
 exec-timeout 0 0
line vty 0 4
 exec-timeout 0 0
 no login
!
end
----------------------------------------------------------------------------

--------------------------------
RouterA#sh frame pvc

PVC Statistics for interface Serial0 (Frame Relay DTE)

DLCI = 200, DLCI USAGE = LOCAL, PVC STATUS = INACTIVE, INTERFACE = Serial0

  input pkts 65 output pkts 43 in bytes 8334
  out bytes 2382 dropped pkts 3 in FECN pkts 0
  in BECN pkts 0 out FECN pkts 0 out BECN pkts 0
  in DE pkts 0 out DE pkts 0
  out bcast pkts 43 out bcast bytes 2382
  pvc create time 00:20:44, last time pvc status changed 00:19:35

FrameSwitch#sh frame pvc

PVC Statistics for interface Serial0 (Frame Relay DCE)

DLCI = 200, DLCI USAGE = SWITCHED, PVC STATUS = INACTIVE, INTERFACE =
Serial0

  input pkts 47 output pkts 70 in bytes 2606
  out bytes 9066 dropped pkts 0 in FECN pkts 0
  in BECN pkts 0 out FECN pkts 0 out BECN pkts 0
  in DE pkts 0 out DE pkts 0
  out bcast pkts 23 out bcast bytes 6486 Num Pkts Switched
47

  pvc create time 00:22:30, last time pvc status changed 00:22:20

PVC Statistics for interface Serial1 (Frame Relay DCE)

DLCI = 210, DLCI USAGE = SWITCHED, PVC STATUS = ACTIVE, INTERFACE = Serial1

  input pkts 47 output pkts 70 in bytes 2580
  out bytes 9092 dropped pkts 0 in FECN pkts 0
  in BECN pkts 0 out FECN pkts 0 out BECN pkts 0
  in DE pkts 0 out DE pkts 0
  out bcast pkts 23 out bcast bytes 6486 Num Pkts Switched
47

  pvc create time 00:22:29, last time pvc status changed 00:22:19
PVC Statistics for interface Serial2 (Frame Relay DCE)

the dlci 200 pvc in always inactive,I check the frame switch but found no
error there.all the encaps and lmi-types are match,anyone offer a hand?
Thanks in Advance.

Frankly speaking this is where I met in the lab in some training
centers,but
when I move the identical config into my home lab,it works,all the pvcs are
active,can anyone tell what the problem is?
----------------------------------------------------------------------------
---------------------

      To receive our special fares directly by email, register at
      http://www.britishairways.com/registration



This archive was generated by hypermail 2.1.4 : Thu Jun 13 2002 - 10:32:48 GMT-3