From: Rivron Francois (Francois.Rivron@xxxxxxxxx)
Date: Fri Dec 07 2001 - 07:28:26 GMT-3
Hello,
my think is as the switch is able to detect a fault at a physical level, the
port state of the redondant link is move directly to listening state. So the
redondant path should be on in 30s.
Francois
> -----Message d'origine-----
> De: Taz Kazam [SMTP:taz_kazam@yahoo.co.uk]
> Date: vendredi 7 dicembre 2001 10:38
> @: thegroup
> Objet: Spantree Timer
>
> Can anyone help.
>
> I've step up four 1900 Catalyst switch in a loop, to
> test spanning tree. One port changes its state to
> blocking, as I expected, however, when I take the
> cable out of the non-redundant path, which cause the
> redundant path to change from blocking to fowarding -
> it does, but it only take 20 seconds. From my reading
> this should take 50 seconds (15sec fwd delay - 20sec
> MaxAge) Blocking -----15-----Listen---
> 15-----Learning----20------Fowarding. Im using the
> default factory settings!
>
> Anyone can help?
>
> Taz.
>
This archive was generated by hypermail 2.1.4 : Thu Jun 13 2002 - 10:32:39 GMT-3