Re: 3 router same problem and not yet solved.

From: Bill Reilly (william.j.reilly@xxxxxxxxxxx)
Date: Sun Nov 11 2001 - 21:34:47 GMT-3


   
I too saw a similar problem, the symptoms where the same, I ended up setting my
stop bits to 2 and flow control to hardware and this cleared up the issue.

I do not know if it is a Windows thing or an IOS thing, I really just wanted to
talk to my routers again.

Bill

Ahmed Mamoor Amimi wrote:

> I have tried this also but didnt help.
> feed me more suggestions.... please.
>
> -Mamoor
>
> -----Original Message-----
> From: nobody@groupstudy.com [mailto:nobody@groupstudy.com]On Behalf Of
> Church, Chuck
> Sent: Friday, October 26, 2001 10:06 PM
> To: 'Ahmed Mamoor Amimi'; 'Ccielab'
> Subject: RE: 3 router same problem and not yet solved.
>
> Try setting the serial port on your PC (assuming it's Windows) to not use
> FIFO buffers. One of my older 2500s did the same thing until I did this.
> The setting is under advanced, I believe. HTH...
>
> Chuck
>
> -----Original Message-----
> From: nobody@groupstudy.com [mailto:nobody@groupstudy.com]On Behalf Of
> Ahmed Mamoor Amimi
> Sent: Friday, October 26, 2001 11:24 AM
> To: Ccielab
> Subject: 3 router same problem and not yet solved.
>
> Hi,
> Lets see who can crack this !!
> This topic is discussed many time but i didn't get any answer then solved my
> problem,anyhow I have 3 routers , two 4500 and one 4700 . non of the console
> works. When i power-on the routers they give me the booting on the console
> but at the end where i have to start it dont accept anything. All of my
> routers gets this problem with in a week. I have applied the following
> solution.
>
> 1- ram change
> 2- flash change
> 3- baudrate change
> 4- flow control none
> 5- scrollock toggle
> 6- hitting space bar at booting to get in to ROMMON
> 7- nothing on AUX port, dont see anything there too. (This is just because
> router didnt finshed booting as the router is on
> asking for the initial config.)
> 8- plugging in and out rapidily when booting.
> 9- tried hyperterminal, secureCRT, tera term
> 10- changed the console cable and converters at the ends.
>
> Any more solution from the group... lets see...
>
> -Mamoor



This archive was generated by hypermail 2.1.4 : Fri Jun 21 2002 - 06:45:12 GMT-3