RE: Dialer profiles again

From: SALMON, MARK (SBMS) (MARK.SALMON@xxxxxxxxxxxx)
Date: Fri Aug 03 2001 - 09:41:08 GMT-3


   
I discovered later hat my config was wrong. I later only had it on one end
and it worked fine with both ends Dialer profile or one end legacy.

Mark Salmon
Sr. WAN Engineer Great Lakes Region
Cingular Wireless
2000 Ameritech Center Drive 3F07B
Hoffman Estates IL 60195
Voice: (847)765-3999
Pager: (847)992-0458
Email: mark.salmon@cingular.com

-----Original Message-----
From: Michael Wong [mailto:Michael.Wong@nec.com.au]
Sent: Thursday, August 02, 2001 7:55 PM
To: Groupstudy - CCIELAB (E-mail)
Subject: RE: Dialer profiles again

I have used dialer profiles and not needed "ip ospf demand-circuit" on both
ends. I only used it on the stub end and it worked fine. The "ip ospf
demand-circuit" should only be used on the stub end. Here are the configs I
used .... hope this helps. (I'm from Australia so I don't need SPIDs)

    (area100) (area0)
|------r1--------r2-------|

r1
interface Dialer0
 ip address 192.168.1.1 255.255.255.252
 no ip directed-broadcast
 encapsulation ppp
 ip ospf demand-circuit
 dialer remote-name p1r3
 dialer string 415*
 dialer pool 1
 dialer-group 1
 ppp authentication chap
!
router ospf 1
 area 100 stub
 network 10.0.0.0 0.0.0.255 area 100
 network 192.168.1.0 0.0.0.255 area 100
 network 192.168.2.0 0.0.0.255 area 100
!

r2
interface Dialer0
 ip address 192.168.1.2 255.255.255.252
 no ip directed-broadcast
 encapsulation ppp
 dialer remote-name p1r1
 dialer string 417*
 dialer pool 1
 dialer-group 1
 ppp authentication chap
!
router ospf 1
 area 100 stub no-summary
 network 192.168.1.2 0.0.0.0 area 100
 network 192.168.1.5 0.0.0.0 area 0
!

-----Original Message-----
From: SALMON, MARK (SBMS) [mailto:MARK.SALMON@cingular.com]
Sent: Thursday, 2 August 2001 1:57 pm
To: 'ccielab@groupstudy.com'
Subject: Dialer profiles again

Hi, I discovered that if you are using dialer profiles, BOTH sides must be
configured for IP OSPF demand for it to work. Did anyone else encounter
this?

Mark Salmon
Sr. WAN Engineer Great Lakes Region
Cingular Wireless
2000 Ameritech Center Drive 3F07B
Hoffman Estates IL 60195
Voice: (847)765-3999
Pager: (847)992-0458
Email: mark.salmon@cingular.com
**Please read:http://www.groupstudy.com/list/posting.html
**Please read:http://www.groupstudy.com/list/posting.html
**Please read:http://www.groupstudy.com/list/posting.html



This archive was generated by hypermail 2.1.4 : Thu Jun 13 2002 - 10:31:44 GMT-3