RE: Problems with Fatkid Lab-212

From: Roger Dellaca (rdellaca@xxxxxxxxxx)
Date: Fri May 11 2001 - 13:39:53 GMT-3


   
the DLCI on the other end can be the same only if going to different destinatio
n interfaces, because you have to put the reverse config on the destination int
erface so it knows how to get back to the source.

>>> "louie kouncar" <lkouncar@UU.NET> 05/11 3:58 AM >>>
Markus,

Your problem is that you are using the same DLCI twice (103), You need
unique DLCI for each PVC on your end,
try 103------->102
    104------->102

The DLCI on the other side can be the same, but on your side it has to be
different or you will get the error message you got.....

Hope this helps.

Louie J. Kouncar
TCO3 Senior Data Center Engineer
UUNET
W-703-343-6645
C-703-304-2460

-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com]On Behalf Of
Markus Haas
Sent: Friday, May 11, 2001 3:25 AM
To: ccielab@groupstudy.com
Subject: Problems with Fatkid Lab-212

Hi,

I want to setup the EIGRP Lab.
I cant't setup the Frame-Relay switch.
When I want to confiure the Frame-Relay switch I have the following
error message

R4(config-if)#frame-relay route 103 interface serial 0/5 102
 R4(config-if)#frame-relay route 103 interface serial 5/0 102
Can't use same dlci on overlapping circuits

Doea anybody agree with me ?

Markus