Re: Point to Point Serial link

From: Todd Veillette (tveillette@xxxxxxxx)
Date: Fri Apr 13 2001 - 07:19:32 GMT-3


   
Eric,

Remember even in point-to-point there is a "pvc" from you to the cloud and
another totally separate
from your customer to the cloud. The dlci's on each router are locally
significant.

Todd

----- Original Message -----
From: "Eric Hauptman" <ehauptma@home.com>
To: "Groupstudy" <ccielab@groupstudy.com>
Sent: Friday, April 13, 2001 5:24 AM
Subject: OT: Point to Point Serial link

> I have a production network where one side of a point to point serial
> link is showing up/down and the other side is showing up/up. I thought
> that if one side went down they would both go down. I know on frame
> relay one can be up/up and the other down, but I thought on a point to
> point this would not be the case. Am I missing something basic here? I
> am running the T1s into 2610 routers with built in WIC-T1-CSUs.
>
> Thanks.
>
> Eric



This archive was generated by hypermail 2.1.4 : Thu Jun 13 2002 - 10:29:45 GMT-3